other
Productos
Reactivo de anticuerpo CD56 para inmunohistoquímica

Reactivo de anticuerpo CD56 para inmunohistoquímica

Anticuerpo IHC -- CD56


  • Control positivo:

    Appendix
  • Localización Celular:

    Cytoplasm/cell membrane
  • Solicitud:

    IHC-P
  • Anticuerpo secundario:

    iVision™
  • Nº de catálogo:

    AM0056
  • Especies anfitrionas:

    Mouse
  • Clon:

    56C04
  • Especificación/ml:

    1、3、6、0.2(Concentrated)

Product name

IHC Antibody --CD56


Packing specification

Code Clone

Specifications

AM0056 56C04

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AM0211 123C3

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml

AR0466 SD361

0.1ml, 0.2ml, 1ml, 1.5ml, 3ml, 6ml, 11ml, 30ml



Intended use

For Research use only. CD56 Antibody reagent is intended for use to qualitatively identify CD56 by microscopy in sections of FFPE tissue using immunohistochemical detection system.


Principle

CD56 is a single transmembrane glycoprotein also known as N-CAM (Neural Cell Adhesion Molecule), Leu-19, or NKH1. In normal tissue, anti-CD56 labels neurons, glia, schwann cells, NK (natural killer) cells, and a subset of T-cells. CD56 expression can be seen in most NK cell neoplasms, certain subtypes of T-cell lymphoma and in some plasma cell neoplasms. Add the primary antibody to bind the antigen on tissue sections, and then use HRP labeled secondary antibody binding primary antibody to form the secondary antibody-primary antibody-antigen complex. When DAB chromogenic solution is added, HRP reacts with enzyme substrate to produce brown insoluble reaction product, which indirectly indicating the existence of antigen. 


Main components

Immunoglobulin, antibody diluent


Storage

Store at 2~8℃ for 18 months


Sample requirements

FFPE tissues are usually cut into sections as thin as 35μm with a microtome. These sections are then mounted onto glass slides that are coated with a tissue adhesive.


Protocol

1. Sample preparationDeparaffinize the slides in xylene , , Ⅲ for 5 minutesTransfer the slides once through 100%, 100%, 95%, 75% alcohols for 2 minutes respectively. Rinse slides with deionized water for 30 seconds.

2BlockingBlock endogenous peroxidase activity by incubating sections in 3% H2O2 solution at room temperature for 5 minutes to block endogenous peroxidase activity. Rinse the slides with deionized water for 30 seconds.

3Antigen retrievalHeat the EDTA Antigen retrieval buffer to 100. Then place the slides in the boiled buffer and continue to heat for 1520 min. Naturally cool down for 30 minutes. Rinse the sample with wash buffer.

4Primary antibody incubation: Drain the slides. Add primary antibody to tissue, incubate at room temperature for 30 minutes. (use antibody diluent or PBS as control). Wash the slides in PBST for 2 times, 5 minutes for each time. If the Primary antibody is concentrated, please dilute it to RTU(ready to use) according to the information on packing. 

5. Secondary antibody: Drain the slides. Add secondary antibody to tissue and incubate at room temperature for 20 minutes. Wash the slides in PBST for 2 times, 5 minutes for each time.

6. DABDrain the slides. Add DAB to the tissue and incubate at room temperature for 5 min. Rinse slides with deionized water.

7. Hematoxylin stainingDrain the slides. Add Hematoxylin to the tissue and incubate at room temperature for 5 minutes. Rinse slides with water. Use the acid solution for differentiation. Rinse slides with water.

8. Deshidratar : Deshidratar los portaobjetos en alcoholes al 75 % , 95 % y 100 %  durante 2 minutos . Seque los portaobjetos. Cubra el tejido teñido con un cubreobjetos usando un medio de montaje. 


Localización positiva

1.  Localización positiva :  membrana/citoplasma .

2.  Control positivo :  amígdala .


Precauciones

1.  Lea atentamente las instrucciones y familiarícese con todos los componentes del kit antes de usarlo. Siga estrictamente las instrucciones durante la operación.

2.  NO use el kit ni ningún componente del kit después de su.

3.  Solo los profesionales capacitados pueden usar este kit. Utilice una bata de laboratorio adecuada y guantes desechables mientras manipula los reactivos.

4.  Evite el contacto de la piel, los ojos y las membranas mucosas con los productos químicos.

5.  NO pipetear con la boca.

6.  Los reactivos no utilizados, el kit usado y los residuos deben eliminarse de acuerdo con las normativas locales.


Fabricante _

Nombre de la empresa: Xiamen Talent Biomedical Technology Co., Ltd

Dirección: Pisos n.º 3 y 4, edificio B10, n.º 2068 Wengjiao Road West, parque biomédico, distrito de Haicang, ciudad de Xiamen, 36100 China

Teléfono: +86 592 6315755            

Correo electrónico : tlsw@talentbiomedical.com                

Sitio web : www.talentbiomedical.com


Símbolos


# Dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.
entregar
#
Productos relacionados
Ver más

Dejar un mensaje

Dejar un mensaje
Si está interesado en nuestros productos y desea conocer más detalles, deje un mensaje aquí, le responderemos lo antes posible.

Hogar

Productos

acerca de

contacto